Because the enclosure of the Guided Wave Radar Level Transmitter Eclipse Model xxx-x1x and xxx-x7x and/or Probe Eclipse Model 7xx-xxx-xxx is made of aluminium, if it is mounted in an area where the use of category 1G apparatus is. ed signal, the Eclipse ® should only be utilised in those interface applications that have clean, distinct layers. The Eclipse ® will tend to detect the top of the emulsion layer. Contact the factory for application assistance. Air εr = 1 Reference signal Time upper level signal 50 mm (2"). Eclipse ® SIL Certified Safety Manual for Enhanced Model AX-XXX 3 Introduction Theory of Operation Guided Wave Radar is based upon the principle of TDR (Time Domain Reflectometry). TDR utilizes high frequency pulses of electromagnetic energy transmitted down a probe. When a pulse reaches a surface that has a higher dielectric.
SIL Certified Safety Manual for ECLIPSE Model 3 Introduction Product Description The ECLIPSE Model High Performance Guided Wave Radar Level Transmitter is a two-wire, loop-powered 24 VDC level transmitter based on Guided Wave Radar (GWR) technology. NOTE: For Safety Instrumented Systems usage, it is assumed that the. ECLIPSE® Level range: mm - 5, mm. Process pressure: bar. Process temperature: °C. The Enhanced ECLIPSE Model is a 24 VDC loop-powered transmitter. It uses guided wave radar (GWR) technology. This single transmitter is suitable for all probe types. It is reliable as it has 91% safe. The Eclipse Foundation - home to a global community, the Eclipse IDE, Jakarta EE and over open source projects, including runtimes, tools and frameworks.
Eclipse® guided wave radar transmitter. The Enhanced Eclipse® Model is a 24 VDC loop-powered transmitter based upon the revolutionary guided wave radar (GWR) technology. This single transmitter can be used with all probe types and offers enhanced reliability, as demonstrated by a Safe Failure Fraction of 91%. options, the Eclipse® transmitter and 7EK GWR probe/cage can also be used in replacing existing Top/Bottom and Top/Side torque tube installations. After removal of the existing torque tube cage assembly (transmitter, controller, and cage), Eclipse Guided Wave Radar may then be installed directly in its place. Several. Read this Manual Before Installing This manual provides information on the Enhanced Eclipse ® Model transmitter with F OU NDATI field - bus™ Output and should be used in conjunction with Eclipse IO manual It is important that all instructions are read and followed carefully. Safety Messages The Eclipse system is designed for use in Category II.
0コメント